To Visit Home-Drives And Control New Zealand - SSD and Eurotherm To Visit Home-Drives And Control New Zealand - SSD and Eurotherm
Download-Resources 
Site map of Drives And Control New Zealand - SSD and Eurotherm Site Map 
Products  Drives  DC Drives
 
AC DRIVES
DC DRIVES
506 507 508 SERIES
512C SERIES
514C SERIES
590H SERIES
590+ SERIES
599 SERIES
590D SERIES
590Link SERIES
SERVO DRIVES
SOFTWARE
Resource Download Prduct Selection Guide Prduct Line-up Chart

506 507 508   Up to 2kW

105W x 140H x 80D mm

User Benefits
  • Low cost/high feature design
  • Compact minimal footprint construction
  • IP20 Protected covers
  • DIN rail mounting
  • Switch selectable 110V or 230V supply
  • Switch selectable tacho or armature voltage feedback

  • The 506, 507 and 508 series drives break new ground in value for money DC motor control. Available in 3, 6 or 12A armature ratings, the feature packed minimum footprint design is ideal for speed or torque control of permanent magnet or shunt wound DC motors from single phase supplies.

    Features:
    User Facilities

  • IP20 Protected covers
  • DIN rail mounting
  • Torque and speed control
  • 2A DC field output
  • Internal 15 second stall detect
  • Internal electronic overcurrent protection
  • Zero speed and drive healthy signal
  • Main and trim setpoint input
  • Independent acceleration and deceleration ramps
  • LED diagnostics


  • Potentiometer Adjustments
  • Maximum speed
  • Minimum speed
  • Current limit
  • Speed stability
  • Acceleration ramp (1 - 15 seconds)
  • Deceleration ramp (1 - 15 seconds)
  • IR compensation


  • Switch Selectable Features
  • Supply voltage 110/230V
  • Tachogenerator/armature voltage feedback
  • Speed calibration
  • Current calibration


  • Power Supply:
    110 - 120V, or 220 - 240V
    10% single phase 50 - 60Hz 5%

    Ambient:
    0 - 45 C, up to 1000m ASL without derating

    Standards:
    CE marked.
    EN50081-1 (1992) (EMC emissions, light industrial with external filter fitted) pr EN50082-2 (1992) (EMC immunity, heavy industrial) VDE 0160 (1994)/pr EN50178 (1995) (safety, low voltage) UL and c-UL designed and submitted



    Back To Top