To Visit Home-Drives And Control New Zealand - SSD and Eurotherm To Visit Home-Drives And Control New Zealand - SSD and Eurotherm
Download-Resources 
Site map of Drives And Control New Zealand - SSD and Eurotherm Site Map 
Products  Drives  DC Drives
 
AC DRIVES
DC DRIVES
506 507 508 SERIES
512C SERIES
514C SERIES
590H SERIES
590+ SERIES
599 SERIES
590D SERIES
590Link SERIES
SERVO DRIVES
SOFTWARE
Resource Download Prduct Selection Guide Prduct Line-up Chart

514C   Up to 9kW

160W x 240H x 90D mm

User Benefits
  • Four quadrant regenerative control
  • 110-500V AC supply selection
  • CE marked and EMC compliant
  • AC power contactor logic and supply
  • Many system features
  • Extremely linear control loops

  • The new regenerative 514C DC thyristor drive offers full four quadrant control of DC motors from single phase supplies. As such it is ideal for applications involving overhauling loads or where rapid and accurate deceleration is required. Together with the non-regenerative 512C they offer the perfect solution for lower power single motor and multi-drive applications.

    Features:
    User Facilities

  • Four quadrant regenerative control
  • Link selection of AC supply voltage
  • Separate AC auxiliary supply
  • AC supply contactor logic
  • 5570 diagnostic compatible
  • Torque or speed control
  • Buffered speed output (10V, 10mA)
  • Buffered ramp output (10V, 10mA)
  • Buffered total setpoint output (10V, 10mA)
  • Buffered current output (10V, 10mA)
  • Three setpoint inputs
  • Torque limit input
  • +10V and -10V analogue reference supplies
  • +24V digital reference supply
  • Health output
  • Zero speed/zero setpoint output


  • Potentiometer Adjustments
  • Maximum speed
  • Minimum speed
  • Current limit
  • Acceleration ramp (1 - 40 seconds)
  • Deceleration ramp (1 - 40 seconds)
  • IR compensation
  • Speed loop gain - proportional
  • Speed loop gain - integral
  • Current gain - proportional
  • Current gain - integral
  • Zero speed offset
  • Zero speed threshold


  • Power Supply:
    Main supply; 110-220V, or 240-500V 10% user selectable. Auxiliary supply; 110 or 230V 10% user selectable. Single phase 50-60Hz 5%

    Ambient:
    0-40 C, up to 1000m ASL without derating

    Overload:
    150% for 15 seconds

    Standards:
    CE marked.
    EN50081-1 (1992) (EMC emissions, light industrial with external filter fitted) pr EN50082-2 (1992) (EMC immunity, heavy industrial) VDE 0160 (1994)/pr EN50178 (1995) (safety, low voltage) UL and c-UL designed and submitted



    Back To Top