Resource Download Prduct Selection Guide Prduct Line-up Chart

599   Integrator Series DC

For connection to remote existing thyristor stacks

User Benefits
  • Open Loop and closed loop winder control
  • Function block programming
  • Common programming, software and fieldbus tools with 690+ AC series
  • Local or remote operator controls
  • Internal controlled field supply
  • DRV option with built-in contactor, fuses and blower starter

  • The totally programmable block diagram of the 599 makes it ideal for the simplest to the most complex applications. Each function block can be simply interlinked to any other in almost limitless combination to provide the exact control strategy required. The 599 is preprogrammed with a configuration for immediate out-of-the-box use. By use of the 6901 or ConfigEd Lite programming software the function blocks can be interconnected to perform the required control action.

    Features:
    6901 Man Machine Interface

  • 32 character back-lit LCD
  • Plain language display
  • Logical menu structures
  • Local control of forward/reverse, run/stop, jog
  • Health, run, local control LED identification
  • Password and function lock-out security
  • Detachable for local or control panel mounting


  • Function Block Programming
  • Inputs and Outputs
  • Local/Remote
  • Winder functions
  • Raise/Lower (digital MOP)
  • Encoder
  • Ramps
  • Field control
  • Jog/Slack control
  • PID control
  • Password
  • Maths and logic functions


  • Inputs/Outputs
    Analogue Inputs: 5 total, 4 configurable
    Analogue Outputs: 3 total, 2 configurable
    Digital Inputs: 9 total, 5 configurable
    Digital Outputs: 3 configurable

    Power Supply
    110-220V 10%; 220 - 500V 10%, three phase 50/60Hz, 500 - 690V 10% on versions above 720A

    Ambient
    0 - 45C (0 - 40 C on versions above 720A) up to 500m ASL without derating

    Fieldbus Options
    Profibus DP
    Modbus RTU
    DeviceNet
    RS422/485 EI Bisynch
    Link fibre optic network

    Feedback Options
    Analogue Tachogenerator
    HTTL Encoder
    Plastic fibre Microtach
    Glass fibre Microtach

    Overload
    Up to 450A : 200% for 10s, 150% for 30s. Various operational overloads apply on higher power frames

    Reference supplies
    +10Vdc, -10Vdc, +24Vdc

    Standards
    CE marked to EN50178 (Safety, Low Voltage Directive) EN50081-2 (1994)(EMC emissions, industrial with external filter fitted) EN50082-2(1995) (EMC immunity, heavy industrial) UL listed to USA and cUL listed to Canadian safety standards up to 720A, pending on larger frames



    Back To Top